Product Code: JLA_15_3_184


Authors:
Thomas H. Dubaniewicz
Kenneth L. Cashdollar
Gregory M. Green
National Institute for Occupational Safety and Health, Pittsburgh Research Laboratory, P.O. Box 18070, Pittsburgh, Pennsylvania 15236


Laser-based instruments are used in areas where coal dust ignition presents a safety hazard. The National Institute for Occupational Safety and Health, Pittsburgh Research Laboratory (NIOSH, PRL) is conducting a study to help determine when an optical beam may be considered a potential ignition source in underground coal mines or coal storage facilities. Researchers conducted experiments to determine threshold igniting powers for Pittsburgh seam bituminous coal dust clouds using an 803 nm continuous wave laser. For fine sized coal dust dispersed in air, concentrations ranging from 600 to 2000 g/m3 were the most easily ignited. A heated layer of coal dust that deposited on the fiber tip during dispersion ignited the dust clouds. Minimum observed igniting powers for laser beams delivered by 200, 400, and 800 μm core fiber optic cables and directed into coal dust clouds were 2.0, 3.0, and 5.0 W, respectively. Threshold igniting power was proportional to beam diameter, and threshold igniting power density decreased with larger fiber diameters. Ignition delay times averaged 0.6 s and did not vary significantly with laser power under initially turbulent test conditions and with flammable targets. Comparisons are made with the results of other researchers. © 2003 Laser Institute of America.

Product Thumbnail

$25.00

Members: $25.00

Note: When applicable, multiple quantity discounts are applied once the items are added to your cart.